Are you in %country%? Do you want to visit our website in another language?

Lung Motion Management1

Precise Treatment
of Tumors in Motion

Watch Patient Case Go to interactive experience

Lung Motion Management1

Precise Treatment
of Tumors in Motion

Lung Motion Management1 aims to enable the imaging of even the smallest of lung tumors in motion for high-precision, non-invasive radiotherapy.

Lung Motion Management1 aims to enable the imaging of even the smallest of lung tumors in motion for high-precision, non-invasive radiotherapy.

Challenges of Lung Tumors in Motion

Each year, more people die of lung cancer than breast, prostate and pancreatic cancer combined2. Lung tumors move during respiration, making them difficult to target during radiotherapy.

Having produced and launched Elements and ExacTrac Dynamic®, Brainlab has gathered extensive experience in treatment planning as well as positioning and monitoring tumors with high precision.

To address the challenges of lung treatments, we are developing the following Lung Motion Management1 workflow to analyze and correlate these types of movements to enable high-precision radiotherapy for lung tumors.

Precise Analysis of Tumor Movement

Four-dimensional computed tomography (4DCT) enables the visualization of a tumor in motion throughout the entire respiratory cycle. Elements Motion Analysis1 identifies visible structures that move along with very small lung tumors (tracking surrogate). Visible bronchi in the surrounding area are then used for orientation and to reliably track tumor movement.

Patient Positioning with State-of-the-Art Imaging Technology

ExacTrac Dynamic® enables millimeter-precise positioning of patients using revolutionary thermal surface camera technology with real-time X-Ray tracking. This facilitates an immediate response to minimal patient movement during irradiation.

Reliable, Real-Time Tumor Tracking1

The tumor movement will be tracked reliably by combining the tracking surrogate with real-time X-Ray images from ExacTrac Dynamic®. A dedicated algorithm is being designed to create a correlation model of the patient’s surface and the internal tumor motion. This will be repeatedly checked and validated during treatment.

Protection of Healthy Tissue
through Targeted Irradiation

Based on the tracking of the tumor movement, the treatment beam can be switched on and off automatically to irradiate the tumor only when it is in the planned area. In the case of lung treatments, this would ensure that healthy lung tissue is protected and that maximum lung function is maintained. At the same time, this treatment method would have the potential to avoid affecting other healthy organ structures.

1

Not all technical capabilities and clinical applications depicted in this section for the purpose of illustrating the product vision are available in the current product release. However, most capabilities are in clinical use in previous product generations. With specific questions reach out to Brainlab.

2

According to the American Cancer Society

Early-stage Lung Cancer Diagnosis –
Treatment with Innovative Technology

Virtual Treatment:
Interactive Session for Understanding Lung Irradiation

FAQ

ExacTrac Dynamic® delivers high-precision radiotherapy by using a thermal surface camera to continuously track the patient’s position during treatment and by verifying the position of the tumor with X-Ray imaging. The ExacTrac Dynamic® system is seamlessly integrated with standard linear accelerators and thereby facilitates efficient and precise treatment sessions for a wide range of indications.

The previous product version, ExacTrac®, enabled us to gather many years of experience and expertise in the irradiation of cranial, spine, prostate and liver tumors. In addition, ExacTrac Dynamic® is also in use for the treatment of breast cancer and, in the future, will be available to use for the treatment of lung cancer. Currently more than 1.000 ExacTrac® and ExacTrac Dynamic® systems are being used clinically worldwide.

4D-CT, or four-dimensional computed tomography, is an advanced imaging method that captures the location and movement of a patient’s tumor and organs over time. 4D-CT is currently used in the field of radiotherapy, especially for liver and lung indications.

To create 4D-CT scans, several standard CT scans are acquired while the patient is breathing freely. The images are then sorted according to the respiratory status. In this way, several “bins” are obtained, each representing a specific respiratory status at a certain time point, which adds the fourth dimension to an otherwise three-dimensional CT-scan.

Ultimately, 4D-CT scans provide a precise analysis of the tumor movement which enables more accurate radiotherapy planning. In this way, radiation is administered either on the entire area in which the tumor moves, the “motion envelope,” or during specific moments of the respiration cycle (currently under development at Brainlab).

The Lung Motion Management method is partially in use through the combination of ExacTrac® and Vero®. However, these products are being used without the support of motion analysis for the localization of very small tumors and without thermal surface camera tracking for continuous monitoring of the patient’s position (infrared markers only). Nevertheless, the Vero® system already works with a correlation model built from temporal information of external respiratory motion (infrared markers) and localized internal target position (X-Ray fluoroscopy). During treatment, the correlation model is used to predict the target position, which can continuously be verified by X-Ray imaging. The information obtained from the verification images can be used to update the correlation model.

* Commercially not available.

The word surrogate means replacement and, in this case, refers to the surrounding tissue of a small lung tumor that moves along with it during respiration. Since very small tumors often cannot be adequately depicted and captured with imaging tools, a tracking surrogate is used to track the movement of the tumor.

Our system will also support DIBH for pulmonary indications, but the choice of treatment approach is and remains up to the treating medical staff. However, based on clinical experience, we know that patients suffering from lung cancer do not breathe in as deeply or cannot hold their breath for a sufficiently long time. With the Lung Motion Management** method, the lung tumor is also irradiated during exhalation, i.e., in the more stable phase of the respiratory cycle.

* Not yet commercially available in several countries. Please contact your sales representative.

**Commercially not available.

The dose of a 2D X-Ray or conventional X-Ray is about fifty times smaller than the dose of a cone-beam CT. (De Los Santos et al., Int J Radiation Oncol Biol Phys, 2013; Cheng et al., Radiat. Prot. Dosim, Vol 175, Iss 3, 2017)